WATERFLOW DETECTOR (WFD SERIES) :.

System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2" through 8", and can be mounted in a vertical or horizontal position.The WFD series consists of a rugged, NEMA 4 rated enclosure.
Designed for both indoor and outdoor use, the WFD series operates across a wide temperature range, from 32°F to 120°F. The WFD series incorporates a mechanical retard feature, which minimize the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard's unique sealed design is immune to dust and other contaminants.
UL Models
WFD20 (2")
WFD25 (2.5")
WFD30 (3")
WFD30-2 (3")
WFD35 (3.5")
WFD40 (4")
WFD50 (5")
WFD60 (6")
WFD80 (8")
Code No Waterflow Detector ( WFD) Series
SWD-065 2.5" ( 65mm ) Waterflow Detector ( WFD25 )
SWD-080 3" ( 80mm ) Waterflow Detector ( WFD30-2)
SWD-100 4" ( 100mm ) Waterflow Detector ( WFD40)
SWD-150 6" ( 150mm ) Waterflow Detector ( WFD60)
SWD-200 8" ( 200mm ) Waterflow Detector ( WFD80)
top
   SUPERVISORY SWITCHES :.
     OSY2 SUPERVISORY SWITCH
The System Sensor OSY2 Supervisory Switch is used to monitor the open position of an OS&Y (Outside Screw and Yoke) type gate valve. Featuring a new mounting bracket, the OSY2 is designed to mount easily to most OS&Y valves ranging in size from 1" to 12". The OSY2 contains two sets of SPDT (Form C) Contacts.

 Code No  Description
SWD-OSY  OSY Supervisory Switch
     PIBV2 SUPERVISORY SWITCH
The PIBV2 consists of a rugged housing, intended for indoor and outdoor use. The PIBV2 features a flexible design that accomodates post indicator, butterfly, and many other types of wall post, recessed wall post and pressure reducing valves. Installation is made easier with the PIBV2's single side conduit entrance. By providing a direct conduit pathway to the electrical source, right angle fittings are not required.
The PIBV2 is equipped with tamper resistant cover screws to prevent unauthorized entry.

 Code No  Description
 SWD-PIBV  PIBV Supervisory Switch
     ALARM PRESSURE SWITCH
System Sensor's EPS 10 Series switches are designed for use in wet , dry, deluge and preaction automatic sprinkler systems to indicate a discharge from a sprinkler. The EPS10-1 has a single SPDT switch while the EPS10-2 model contains two SPDT switches. The EPS10 Series features field adjustable pressure sensitivity to provide an alarm response between 4 to 20 psi.

 Code No  Description
 SWD-APS  Alarm Pressure Switch
   Approval :

   Waterflow Detector ( WFD Series )
   Supervisory Switches & Alarm Pressure Switch

 
   Bomba Approved (Fire & Rescue Department, Malaysia)
 
UNIQUE FIRE INDUSTRY SDN BHD
No. 16, Jalan BK 1 / 12, Kinrara Industrial Park,
Bandar Kinrara, Jalan Puchong,
47100 Selangor, Malaysia.

Tel : 603-8076 1880 / 8076 1841 / 8076 1842    
Fax : 603-8076 1862
 
Website : http://www.uniquefire.com
E-mail :  enquiry@uniquefire.com

guest1.gif (1837 bytes)

I Main I Corporate Profile I Enquiries I
I
68L (45Kg) CO2 Seamless Cylindes I 2Kg CO2 Portable Fire Exinguisher I Fire System FM-200 I Fire Suppression for Commercial Cooking Application I Hartindo AF11E, AF21, AF31 ISprinkler System "Globe" I Sprinkler System "System Sensor" I Automatic Sprinkler CD I Wet & Dry Riser System - Fire Hose Yama I Wet & Dry Riser System - Fire Hose Commander I Pyroprotect & Premier I Red Viking Hose I Fire Alarm Systems 'System Sensor' I Fire Alarm Systems & Equipment I Fire Maintenance Battery I Fire Blanket I Refilling Series For Fire Extinguisher I   Fire Fighting Products & Equipments I Clevis Hanger CL TypeITerms and ConditionsI

Designed and Maintained by WebWork-Solutions.com Copyright © 2000 - .